Buying an electric car is the exciting decision. Installing charging at home is the practical one, and it is where many owners discover that the electrical service they have is not the service they imagined. The good news is that almost every home can charge an EV safely. The bad news is that the cheapest quote is often the one that ignores the load calculation.
This guide covers the questions an electrician will ask, in language an owner can follow, so the conversation starts in the right place.
Power in plain numbers
Charging speed is set by power, and power is voltage multiplied by current. A standard household outlet in many markets provides around 2.3 kW. A dedicated level 2 circuit typically provides 7 kW, 11 kW or more, depending on the supply and the vehicle's onboard charger.
As a rough guide:
- 2 kW adds roughly 8–12 km of range per hour, depending on the car.
- 7 kW adds roughly 30–50 km per hour.
- 11 kW adds roughly 50–80 km per hour, if the car can accept it.
Those numbers are estimates, not promises. Efficiency, temperature, battery state and the car's charging curve all change the result. What matters at home is overnight: a 7 kW charger usually refills a typical daily commute in two to four hours.
Panel capacity and load
Every electrical service has a maximum capacity, and every panel has a set of existing loads. An electrician performs a load calculation that adds the continuous loads — lights, outlets, water heater, air conditioning, oven — and checks the spare capacity against the proposed charger.
The charger is a continuous load, so it is sized with a safety margin. A 32 A charger on a 40 A circuit is typical, but the exact figures depend on local code and the equipment.
If the panel is full, the options are:
- Upgrade the service to a larger supply. Effective, expensive and sometimes slow to arrange.
- Use a load-management device that pauses or reduces charging when the house draws near its limit.
- Choose a lower-power charger that fits the available capacity.
- Time the charge for off-peak hours when other loads are low, though this alone is not a substitute for a proper calculation.
Do not accept a quote that does not include a load calculation. A charger that trips the main breaker on a cold evening is a design failure, not bad luck.

Level 1 or level 2
Level 1 charging uses a standard outlet and the portable cable that usually comes with the car. It is slow but adequate for low-mileage drivers, plug-in hybrids and overnight top-ups. It requires a dedicated, properly rated outlet — not an extension lead — and the outlet should be inspected for condition.
Level 2 charging uses a dedicated circuit and a wall-mounted unit. It is the sensible default for a full EV used daily. It also supports scheduled charging, which lets owners take advantage of cheaper overnight tariffs.
Level 2 is not automatically better for everyone. If the car is small, the commute is short and the panel is tight, level 1 may cover the need. But for a household with two cars or a long commute, level 2 removes the daily planning that makes EV ownership tiring.
Choosing a wallbox
Wallboxes differ in more than price. Features worth considering:
- Safety certification for your region. This is non-negotiable.
- Current rating and adjustability, so the unit can be set to the available supply.
- Load management, either built in or via a compatible energy meter.
- Scheduling and tariff integration, ideally without depending on a fragile cloud service.
- Cable length and holster, matched to where the car parks.
- Weather rating if the unit is installed outdoors.
- Local support and warranty, because a failed charger is a household problem.
A smart charger is useful, but the basics matter more: correct circuit, correct protection, correct earthing and a neat, accessible installation. Avoid units that require an always-on internet connection for basic charging.

Installation and permits
EV charging installation is licensed electrical work in most places, and it often requires a permit and an inspection. The details vary, but a proper installation includes:
- A dedicated circuit with the correct cable size and protection.
- RCD or GFCI protection appropriate to the charger and local code.
- Correct earthing and bonding.
- Protection from physical damage, water and sunlight.
- A isolator or means of safe isolation near the unit.
- Documentation and testing, including a certificate.
Choose an electrician who has installed EV chargers before and who will discuss cable routing, trenching and the location of the unit before quoting. The cheapest quote often excludes making good, conduit, trenching or the permit fee.
If you rent, get written permission and confirm who owns the installation. If you live in an apartment, a shared or communal charging solution may be the only viable option.


The bottom line
Start with the panel, not the charger. Get a load calculation, decide between level 1 and level 2 based on real daily mileage, and choose a certified unit with the features you will actually use. Have the work permitted, inspected and documented.
The installation should be invisible in daily life: plug in, walk away, drive off in the morning. If charging requires planning, apps and workarounds, the system was undersized or overcomplicated. Fix it once, properly, and the car becomes simpler rather than more demanding.